Ventsure 4 foot strip heat moisture ridge vent 27 lineal feet required.
Roof ventilation requirements.
The key to proper ventilation of your roof and attic is balance.
Measure the length and width of the attic floor space to be ventilated.
Industry standard for proper attic ventilation recommends for no vapor retarder type of attic insulation no paper plastic or aluminum layer between the attic floor and insulation layer 1 sq.
Attic ventilation requirements how many attic vents your roof needs.
Most building codes require a ratio of 1 150 ventilation space to attic floor space.
R806 1 ventilation required enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow.
You can also contact your local municipality to check on building code in your area.
Roof vents choose one of the following products to meet the recommended exhaust nfva of 528 square inches.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
You can calculate attic ventilation requirements by determining the square footage of your attic floor its width times its length and compare that to the total required net free area nfa.
Ventilation of attic spaces is required by most building codes as well as by roofing material manufacturers and the national roofing contractors association nrca.
Foot of ventilation for every 150 sq.
Ventilation openings having a least dimension larger than 1 4 inch 6 4 mm shall be provided with corrosion resistant wire cloth screening hardware cloth perforated vinyl or similar material with openings having a least dimension of 1 16 inch 1 6 mm minimum and 1 4 inch 6 4 mm maximum.
Proper attic ventilation consists of a balance between air intake at your eaves soffits or fascias and air exhaust at or near your roof ridge.
Blocking and bridging must be arranged so they do not interfere with air movement.
Air space no less than 1 inch must be provided between any insulation or obstruction and the roof sheathing.